[Contents] [Prev] [Next] [Index] [Report an Error] [No Frames]


Creating CBF Interface Connections

You can create a CBF interface connection either through the SMDS Tunnel Connection dialog box or by executing an Associate Tunnel Interface action or an Associate HSSI Interface action.

The following procedure illustrates the creation of a CBF interface connection by means of an Associate HSSI Interface action:

  1. In the Device-wide Explorer, select IP Tunnel, right-click, and select List All.

The list of IP tunnel interfaces appears in the list area.

  1. Click the appropriate IP tunnel interface.
  2. Right-click, and select Associate HSSI Interface.

The Associate HSSI Interface with GRE Tunnel Interface dialog box appears.

  1. To select the high-speed serial interface (HSSI) line interface, click Select Interface.

The Select Available HSSI Line Interface dialog box appears.

  1. Select the line interface you want, and click OK.

The line interface's slot and port numbers appear in the HSSI Line Interface group box in the Associate HSSI Interface with GRE Tunnel Interface dialog box.

  1. Set the parameters for the GRE tunnel interface (Table 74).
  2. 
    
    
    
    Table 74: GRE Tunnel Parameters
    Parameter
    Description

    MTU

    Maximum transmission unit; range 1024-10240; default 10240. To function effectively, the MTU value must be the same for both endpoints.

    Source: IP Address

    Source IP address for the tunnel interface

    Destination IP Address

    Destination IP address for the tunnel interface

    
    

    NOTE: You can set the IP address parameters either by typing the address in the text fields or by clicking the buttons and selecting the addresses from the related dialog box that appears.

  3. Click OK.

The CBF interface connection is created.