Configuring POS
> Creating POS Interfaces
Creating POS Interfaces
In the NMC-RX application, you need to navigate to the module's line interface level to create a POS interface for the module.
To create a POS interface:
- In the Instance Explorer, select the module on which to create a POS interface.
- Select the line interface, right-click, select Create, and click POS Interface.
The Create POS Interface dialog box appears.
- Set the POS interface parameters (Table 78).
Table 78: POS Interface Parameters
|
|
Name
|
Identifies the interface; generated automatically
|
Alias
|
Description of the interface; 0-15 characters; default: blank
|
IfIndex
|
Identifies the interface on the particular line interface; generated automatically
|
Operational
|
Current operational status of the interface
|
Administrative
|
Desired status of the interface: Up/Down; default: Up
|
|
CRC Checking Enabled
|
Cyclical redundancy check (CRC); an error-checking technique in which the frame recipient calculates a remainder by dividing frame contents by a prime binary divisor and compares the calculated remainder to a value stored in the frame by the sending node
|
Data Inversion
|
Enables inversion of binary 0s and 1s. The purpose of data inversion is to provide ones density, a method for inserting 1s in the data stream. If you enable data inversion on your device, be sure it is also enabled on the destination device.
|
MTU
|
Maximum transmission unit; largest size allowed for a data packet transmitted over a transmission line; range 4-32763; default 1600
|
MRU
|
Maximum receive unit; largest size allowed for a data packet received over a transmission line; range 4-32763; default 1600
|
CRC Algorithm
|
Cyclical redundancy check (CRC); can be set to 16 bit or 32 bit; default 16 bit
|
- Click OK to save the settings.
A Cisco HDLC, Frame Relay, or PPP interface can now be created on the new POS interface.