Configuring Ethernet Modules
You can configure the admin status of a module only by enabling or disabling it.
To change the admin status:
- In the Instance Explorer list, select the module that you want to configure.
- Right-click, and select Configure.
The Module Config tab appears in the work area.
- Set the admin status (Table 43).
Table 43: Module Configuration Parameters
|
|
Module Type
|
Module type (cannot edit)
|
Admin Status
|
- Enabled—Module is running
- Disabled—Module is not in operation
|
Serial Number
|
Ten-digit identification number (S/N) on the face plate of the module. This value is automatically retrieved from the device, and you cannot edit it.
|
IOA Serial Number
|
Ten-digit identification number (S/N) on the face plate of the input/output adapter. This number is automatically retrieved from the device, and you cannot edit it.
|
- Click Save.
Configuring a Line Interface
There are two line interfaces (0, 1) for the FE-2 module, eight line interfaces (0-7) for the FE-8 module, and one line interface (0) for the GE module.
To configure a line interface:
- In the Instance Explorer, select the line interface that you want to configure.
- Right-click, and select Configure.
The Config tab (either FE Config or GE Config) appears in the work area.
- Set the parameters (Table 44).
Table 44: Line Interface Parameters
|
|
Name
|
Identifies the interface; generated automatically
|
Alias
|
Description of the interface; 0-15 characters; default: blank
|
IfIndex
|
Identifies the interface on the particular line interface; generated automatically
|
Operational
|
Current operational status of the interface
|
Administrative
|
Desired status of the interface: Up/Down; default: Up
|
Speed
|
Specifies the line speed for a Fast Ethernet or Gigabit Ethernet interface:
- auto—Automatically specifies that the system negotiates the line speed with the remote device
- 10—Specifies that the device uses a line speed of 10 Mbps (FE only)
- 100—Specifies that the device uses a line speed of 100 Mbps (FE only)
- 1000—Specifies that the device uses a line speed of 1000 Mbps (GE only)
|
Operational Duplex Mode
|
Specifies the current operational duplex mode for the Ethernet interface
|
Duplex Mode
|
Specifies the duplex mode for a Fast Ethernet or Gigabit Ethernet interface:
- auto—Automatically specifies that the system negotiates duplex mode with the remote device
- half—Specifies that the device uses half-duplex (FE only)
- full—Specifies that the device uses full-duplex on the interface
|
MTU
|
Maximum transmission unit; range 64-9188; default 1518
|
- Click Save.
 |
NOTE: When you set the duplex mode to a value other than "auto," you must simultaneously set the corresponding speed parameter to a value other than "auto." Therefore, the operational duplex mode can be different from the administrative duplex mode.
|